MPPC S13360-3075CS

S12572-010C,S12572-015C,etc
Datasheet [453 KB/PDF]

The S13360 series is an MPPC (SiPM) for precision measurement. It inherits the superb low afterpulse characteristics of its predecessor and further provides lower crosstalk and lower dark count. They are suitable for precision measurement, such as flow cytometry, DNA sequencer, laser microscope, and fluorescence measurement, that requires low noise characteristics.


Features
-Reduced crosstalk and dark count (compared to previous products)
-Outstanding photon counting capability (outstanding photon detection effeciency against incident photons)
-Compact
-Operates at room temperature
-Low voltage operation
-High gain
-Excellent time resolution
-Immune to the effects of magnetic fields
-Operates with simple readout circuits

Specifications

Package type Ceramic
Number of channels 1 ch
Effective photosensitive area / ch 3 × 3 mm
Number of pixels /ch 1600
Pixel size 75 μm
Spectral response range 270 to 900 nm
Peak sensitivity wavelength (typ.) 450 nm
Dark count/ch (typ.) 500 kcps
Terminal capacitance/ch (typ.) 320 pF
Gain (typ.) 4.0×106
Measurement condition Ta=25 ℃

Dimensional outline (unit: mm)

KAPDA0156

Related documents

Recommended products

Disclaimer [66 KB/PDF]